The SBI12-LLD is a microprocessor-controlled Load Disconnect Isolator. The SBI12-LLD is designed specifically for use in LiFePO4 battery applications as a system to protect the lithium battery from being excessively discharged by auxiliary loads.

Or 4 easy payments of $47,57 with Afterpay info

Artikelnummer: SBI12-LLD
$190.25 (AUD)

The SBI12-LLD is a microprocessor-controlled Load Disconnect Isolator. The SBI12-LLD is designed for use in lithium battery applications (LiFePO4) as a system to protect the battery from being excessively discharged by auxiliary loads, enabling the auxiliary battery to remain above the level at which internal protection circuitry would activate. Falling below this threshold would prevent many chargers from recharging the battery.

Put simply, once the auxiliary battery has been overly discharged, the Load Disconnect Isolator will turn off any connected loads. Similarly, if the battery climbs back above a suitable level, the Load Disconnect Isolator will restore power to the connected loads.

 

Spike protection

 

The SBI12-LLD Smart Start battery isolator incorporates a number of spike protection components specifically designed to reduce the risk of damaging the unit. It is also designed to prevent any spikes generated by the solenoid coil from affecting vehicle equipment.

 

Features

  • Overmould design
  • Compact in size and easy to install
  • Silver contacts for longer life and suitable for marine applications
  • Power saving technology
  • Fault indication
  • Fully surge protected

 

Quality fuse kits

 

Installation of REDARC smart battery isolators should also see the use of quality fuse kits.

 

To view product flyer, click here.

Not sure what dual battery system is best for your vehicle? Let Shaun Whale explain more.

 

The SBI12-LLD is a microprocessor-controlled Load Disconnect Isolator. The SBI12-LLD is designed for use in lithium battery applications (LiFePO4) as a system to protect the battery from being excessively discharged by auxiliary loads, enabling the auxiliary battery to remain above the level at which internal protection circuitry would activate. Falling below this threshold would prevent many chargers from recharging the battery.

Put simply, once the auxiliary battery has been overly discharged, the Load Disconnect Isolator will turn off any connected loads. Similarly, if the battery climbs back above a suitable level, the Load Disconnect Isolator will restore power to the connected loads.

 

Spike protection

 

The SBI12-LLD Smart Start battery isolator incorporates a number of spike protection components specifically designed to reduce the risk of damaging the unit. It is also designed to prevent any spikes generated by the solenoid coil from affecting vehicle equipment.

 

Features

  • Overmould design
  • Compact in size and easy to install
  • Silver contacts for longer life and suitable for marine applications
  • Power saving technology
  • Fault indication
  • Fully surge protected

 

Quality fuse kits

 

Installation of REDARC smart battery isolators should also see the use of quality fuse kits.

 

To view product flyer, click here.

Not sure what dual battery system is best for your vehicle? Let Shaun Whale explain more.

 

Produktspezifikation
Attribute name Attribute value
System Voltage 12V Nominal
Turn ON Voltage 11.0V
Turn OFF Voltage 10.5V
Turn ON Delay 10 sec
Max. Cont. Current 100 Amps
Turn OFF Delay 2 sec
Max. Inrush Current 400Amps
Standby Current < 5mA
Operating Current <0.1A
Dimensions 75 x 70 x 80mm
Weight (g) 200
Warranty 2
Standards CE, C-Tick, AS/NZS CISPR11:2004
Main Stud Torque 5-6.2 Nm
Schreiben Sie Ihre eigene Bewertung
*
*
Schlecht
Sehr gut
Vorliegende Bewertungen
SBI-LLD with MANAGER 30 with LIFEPO4 Battery
First of all, the Manager 30 is really an impressive bit of kit and I'm using it to charge a Lithium battery. With excessive discharge, however, the need of the SBI-LLD becomes important. Don't seem to be able to install it even after following the manual??
Gast | 22.11.2019 22:07
War die Bewertung hilfreich? Ja Nummer (0/0)
Reply from REDARC
The Lithium Load disconnect is recommend for Lithium battery installations and are simple to install and setup. It appears you are experiencing some technical issues. We have a team of qualified technical support members that can assist you further with your enquiry, please contact our technical support line on (08) 8322 4848
Clayton | 25.11.2019 09:56
War die Bewertung hilfreich? Ja Nummer (0/1)
Produktspezifikation
Attribute name Attribute value
System Voltage 12V Nominal
Turn ON Voltage 11.0V
Turn OFF Voltage 10.5V
Turn ON Delay 10 sec
Max. Cont. Current 100 Amps
Turn OFF Delay 2 sec
Max. Inrush Current 400Amps
Standby Current < 5mA
Operating Current <0.1A
Dimensions 75 x 70 x 80mm
Weight (g) 200
Warranty 2
Standards CE, C-Tick, AS/NZS CISPR11:2004
Main Stud Torque 5-6.2 Nm
Benutzer, die diesen Artikel gekauft haben, haben auch gekauft

Sicherungssatz 60 A

FK60
Der REDARC-Sicherungssatz 60 A ist für die einfache, ordentliche Installation von Sicherungen für duale Akkusysteme konzipiert.
$74.12 (AUD)

Sicherungssatz 40 A

FK40
Der REDARC-Sicherungssatz 40 A ist für die einfache, ordentliche Installation von Sicherungen für duale Akkusysteme konzipiert.
$74.12 (AUD)

Eingebauter DC-Ladewandler, 50 A, mit Dualeingang

BCDC1250D
Der REDARC BCDC1250D ist ein eingebauter DC-DC-Ladewandler mit 12 V/50 A. Er beinhaltet REDARCs preisgekrönte Kfz-Ladetechnologie und kann von Solar- und Gleichstromeingängen gleichzeitig laden
$793.11 (AUD)