The SBI12-BLD is used in conjunction with a REDARC Manager15 or Manager30 BMS in a 12v negative ground automotive system to protect the auxiliary battery from excessive discharge.
SKU: SBI12-BLD
$181.08 (AUD)

The SBI12-BLD is used in conjunction with a REDARC Manager15 or Manager30 BMS to protect the auxiliary battery from excessive discharge. Specifically designed for use as the load disconnect solenoid controlled by the BMS, the black (earth wire) should be connected to the load pin of the BMS.

The BMS sets the turn on and turn off points through its settings and switches this black wire (earth when loads should be on, no earth when loads should be off), and there is additional voltage thresholds monitored by the Smart Start SBI12-BLD to ensure reliable solenoid engagement.

  

Voltage spike protection

 

The SBI12-BLD smart start battery isolator incorporates a number of spike protection components specifically designed to reduce the risk of damaging the unit, and is designed to prevent any spikes generated by the solenoid coil from affecting vehicle equipment.

 

Features

  • Overmould design
  • Compact in size and easy to install
  • Silver contacts for longer life and suitable for marine applications
  • Power saving technology
  • Fault indication
  • Fully surge protected

The SBI12-BLD is used in conjunction with a REDARC Manager15 or Manager30 BMS to protect the auxiliary battery from excessive discharge. Specifically designed for use as the load disconnect solenoid controlled by the BMS, the black (earth wire) should be connected to the load pin of the BMS.

The BMS sets the turn on and turn off points through its settings and switches this black wire (earth when loads should be on, no earth when loads should be off), and there is additional voltage thresholds monitored by the Smart Start SBI12-BLD to ensure reliable solenoid engagement.

  

Voltage spike protection

 

The SBI12-BLD smart start battery isolator incorporates a number of spike protection components specifically designed to reduce the risk of damaging the unit, and is designed to prevent any spikes generated by the solenoid coil from affecting vehicle equipment.

 

Features

  • Overmould design
  • Compact in size and easy to install
  • Silver contacts for longer life and suitable for marine applications
  • Power saving technology
  • Fault indication
  • Fully surge protected
Products specifications
System Voltage 12V Nominal
Turn ON Voltage 10.2V
Turn OFF Voltage 10.0V
Turn ON Delay 5 sec
Turn OFF Delay 10 sec
Max. Cont. Current 100 Amps
Max. Inrush Current 400Amps
Standby Current < 5mA
Operating Current <0.1A
Dimensions 75 x 70 x 80mm
Weight (g) 200
Warranty 2
Standards CE, C-Tick, AS/NZS CISPR11:2004
Main Stud Torque 5-6.2 Nm
Write your own review
  • Bad
  • Excellent
Products specifications
System Voltage 12V Nominal
Turn ON Voltage 10.2V
Turn OFF Voltage 10.0V
Turn ON Delay 5 sec
Turn OFF Delay 10 sec
Max. Cont. Current 100 Amps
Max. Inrush Current 400Amps
Standby Current < 5mA
Operating Current <0.1A
Dimensions 75 x 70 x 80mm
Weight (g) 200
Warranty 2
Standards CE, C-Tick, AS/NZS CISPR11:2004
Main Stud Torque 5-6.2 Nm